Aqua Medic Marin Control Digital (mcd)
Handheld electronic test meter for temperature, salinity and specific gravity. Measuring range: Temperature 0-100°C. Salinity 5-40 g/l. Specific gravity 1.000-1.032. CLICK FOR MORE INFORMATION
|
|
|
Aqua Medic pH controller set
The pH controller is a precision instrument for controlling the pH value in aquaria. In combination with a CO2 system and a solenoid valve the pH can be maintained at a constant level, and the CO2 supply to aquatic plants or into a Calcium Reactor can be controlled. The unit is supplied with a large LED display, and the control range is digitally adjustable from pH 3.5 to 10.5. The pH controller has a BNC connection for pH electrodes. This set includes pH 2001C, solenoid valve, electrode holder, electrode and calibration fluids pH4, pH7 and pH9. CLICK FOR MORE INFORMATION
|
|
|
Aqua Medic pH controller (without sensor)
The pH controller is a precision instrument for controlling the pH value in aquaria. In combination with a CO2 system and a solenoid valve the pH can be maintained at a constant level, and the CO2 supply to aquatic plants or into a Calcium Reactor can be controlled. The unit is supplied with a large LED display, and the control range is digitally adjustable from pH 3.5 to 10.5. The pH controller has a BNC connection for pH electrodes. Sensor is not included and must be bought seperately. CLICK FOR MORE INFORMATION
|
|
|
Aqua Medic pH computer
The Aqua Medic pH Computer utilises a modern microprocessor, which provides high precision measurement and control. The
membrane front provides waterproof touch keys with which to set the operating valves and calibrate the electrode. The pH Computer is used to control precise values of pH in the aquarium or the Aqua Medic Calciumreactor. The switching band (hysteresis) is adjustable over a wide range and the control direction can be set upwards or downwards. The status of the direction of control and the output are shown on LED’s. The computer can switch up to 500 watts using the supplied external electrical socket. When the calibration key has been selected the unit will automatically calibrate itself to the electrode. A plastic shafted pH electrode with BNC fitting and the correct calibration fluids are included. CLICK FOR MORE INFORMATION
|
|
|
Aqua Medic Light computer
The Aqua Medic Light Computer is designed to accurately simulate nature's own lighting. It is supplied with three separate programmable channels:
Channel One controls the primary lamp (e.g. metal halide, maximum 500 watts).
Channel Two controls additional lighting (e.g. blue fluorescent, maximum 300 watts)
The third channel, a special feature of the computer, controls an incandescent night lighting circuit to a maximum of 100 watts. The night light’s intensity is controlled using an internal programme to simulate the natural lunar cycle of 28 days. The combination of all three channels completely simulates the dusk to dawn lighting cycle. This cycle is of major importance for many plants and animals in setting a rhythm for their reproductive cycle. CLICK FOR MORE INFORMATION
|
|
|
Aqua Medic mV controller - Redox-potential (ORP) monitor and controller
The mV Controller is designed for monitoring and controlling the redox potential (or ORP - oxidation-reduction potential) in aquaria. The unit has a broad controlling range from -500 to a +500 mV, and a measuring range from -1000 to +1000 mV. It can be used to control the supply of ozone in salt water aquaria and / or for the control of nitrate removal in anaerobic biological filters (Aqua Medic Nitratereductor). The unit is supplied with a BNC connection for an mV probe. The use of an original Aqua Medic plastic shafted electrode is recommended. CLICK FOR MORE INFORMATION
|
|
|
Aqua Medic mV computer - Microprocessor controlled redox-potential (ORP) monitor and controller
The Aqua Medic mV Computer uses the same microprocessor technique as the pH Computer. Waterproof touch keys are
used to set the required values and calibrate the electrode. The mV Computer is ideal for controlling anaerobic biological filters such as the Aqua Medic Nitratereductor which have negative redox potential or can control the supply of ozone to the aquarium, or monitor the aquarium water’s redox potential.
All these functions are possible due to the computer’s broad measurement and control range of –500 to +1000 mV.
The direction of control can be set upwards or downwards. The status of the direction of control and the output are shown on LED’s. A plastic shafted mV electrode with a BNC fitting and calibration fluid is included. CLICK FOR MORE INFORMATION
|
|
|
Aqua Medic LF controller - Conductivity monitor and controller
The salt content of water can be determined by measuring the electrical conductivity.
A special feature of the LF controller conductivity monitor and controller is the broad measurement and control range which is divided into 2 bands: from 0 to 2000 µS, the unit is used for monitoring desalinated water and fresh water, and in the range 0 to 200 mS, it is used for brackish and salt water. The unit can therefore be used for the control of reverse osmosis units, for monitoring breeding tanks with soft water, and for the control of the salt content in marine aquaria. The unit is supplied with a directly connected, salt water resistant graphite electrode. CLICK FOR MORE INFORMATION
|
|
|
|
|
|
|
Aqua Medic T computer-Set (Microprocessor controlled temperature monitor and controller)
The T Computer is a precise multi-functional temperature controller and is complete with a digital temperature sensor. The mode of operation can be set using the function keys, either as a heater or cooler controller. In ”heating” mode, the temperature is controlled to the set value using a proportional pulse system with an accuracy of ±0.1°C. In the ”cooling” mode, the accuracy is ±0.5°C. The maximum operating power is 1000 watts for heaters and 600 watts for coolers. CLICK FOR MORE INFORMATION
|
|
|
Aqua Medic Wave (A four channel pump controller)
The Aqua Medic wave is a microprocessor based controller that can operate up to three circulation pump circuits and one filter pump circuit, to simulate natural surge and wave effects. The wave can activate the pumps in 8 different programs to simulate many different current patterns. Between zero and three pumps operate at any one time. The activation frequency can be adjusted. The fourth channel (filter pump) runs continuously but when feeding the aquarium’s inhabitants, especially invertebrates with planktonic food, a feeding pause button can be activated which stops all the pumps, including the filter pump, for approximately 10 minutes. An integrated light sensor ensures that during darkness no more than one circulation pump is active at any time. Each channel can be used for Ocean Runner pumps or powerheads up to a loading of 100 watts. CLICK FOR MORE INFORMATION
|
|
|
|
|
Aqua Medic Glass pH sensor
A laboratory standard sensor for very high accuracy which fits the Aqua Medic pH controllers. CLICK FOR MORE INFORMATION
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|